SINGLE POINT / PLATFORM WEIGHING / OEM
Single point load cells.
Every corner.
Industrial single point load cells for off-center compensated bench, packaging & washdown weighing.
Build the platform around the sensor. Match platter dimensions, gross load and operating environment before choosing the signal chain.
CAPACITY IS ONLY HALF THE SELECTION
What size platform will your sensor carry?
Compare the sensor and platter together. Tare, corner loading and dynamic forces belong in the same calculation.
Daily washdown
Welded stainless configurations, cable protection and a cleaning exposure review.
Select for washdownAUTOMATION / SPL-ALU + CMPFast packaging cycles
Compact flexures, controlled load introduction and a realistic settling-time budget.
Compare aluminum seriesLARGE PLATFORMS / SPL-HVYMore deck. One sensor.
Review heavy-capacity and 800–1,000 mm platter targets against the exact configuration.
Review heavy platformsTHE SPL SELECTION RANGE
Start with the sensing body. Finish with the module.
SPL-ALU
Aluminum single point load cells
3–200 kg selection requests
300 × 300 to 600 × 600 mm requested envelope
Review selection inputsSPL-SSW
Stainless washdown single point load cells
3–1,000 kg selection requests
400 × 400 to 800 × 800 mm requested envelope
Review selection inputsSPL-CMP
Compact checkweigher single point load cells
3–100 kg selection requests
Submit the belt deck or platter dimensions
Review selection inputsSPL-HVY
Heavy-duty large-platform single point load cells
500–2,000 kg selection requests
800 × 800 / 1,000 × 1,000 mm qualification targets
Review selection inputsSPL-BASE
Overload-stop bench scale base frames
Matched to the chosen sensor and platen
300 × 300 / 400 × 500 / 600 × 600 mm frame requests
Review selection inputsOFF-CENTER COMPENSATION
Position changes. The weighing task stays the same.
A single point sensor uses a compensated flexure geometry to reduce changes in output as a load moves around the platform. The beam still experiences force and moment; compensation does not remove mechanical stress.
Useful accuracy depends on the specified platform size, eccentricity, mounting rigidity, temperature and the chosen sensor grade. Validate the assembled scale at its center and corners.
Review the mounting load pathENGINEER THE BASE BEFORE THE PLATTER
A clear flexure. A controlled stop.
Spacer blocks keep the active beam clear of the base and platform. Correctly adjusted center and corner stops limit travel beyond normal weighing.
A stop is part of the complete mechanical design. Its gap must come from actual deflection and tolerance data, rather than a universal clearance rule.
Design the mounting baseEXISTING HBM / ANYLOAD / TEDEA / FLINTEC / ZEMIC
Replacement begins with a drawing.
Shared capacity and mV/V output do not establish mechanical or metrological compatibility.
Questions before freezing the platform design
Does off-center compensation mean zero error?
No. It reduces position-related error within the rated platform and eccentric-load conditions. The installed scale still needs corner-load and calibration verification.
Can one sensor replace a four-cell platform?
Potentially, within the selected single point sensor’s platform and moment limits. Frame stiffness, tare, shock loads and service access must be assessed before changing architecture.
Do C3 or C6 apply to every SPL configuration?
No blanket certification is claimed. Request the exact model, capacity and applicable certificate scope; finished-scale approval is a separate assessment.
CAPACITY + PLATFORM + ENVIRONMENT
Specify the entire load path.
Send the platform size, gross load, mounting drawing and production quantity.